Analysis and elimination of common failure causes of CNC bending machine

发布时间:2018/10/15 11:46:56

First, the oil pump noise is too large (heat is too fast), the oil pump is damaged
1. The oil pump suction line leaks or the tank liquid level is too low, causing the oil pump to suck.
2. The oil temperature is too low, the viscosity of the oil is too large, resulting in large oil absorption
resistance.
3. The oil suction filter is blocked and the oil is dirty.
4. The pump is damaged (when the pump is installed) is hit by any knock.
5. Coupling installation problems, such as axial overtightening, motor shaft and oil pump shaft are not
the same.
6. After the pump is installed, the machine will be reversed for a long time or not refueled.
7. The outlet high pressure oil filter is blocked or the flow rate is not up to standard.
8. The oil pump is empty (oil is present, but there is air at the oil pump suction port).
9. If it is a plunger pump, it may be that the return line is set too low.
10. If it is a HOEBIGER oil pump, it may be deflated.
11. The oil temperature is too high, resulting in a decrease in viscosity (within 60 ° C).
12. Hydraulic oil contains water, which may cause damage to the high pressure filter plug.


Second, the system can not build up without pressure or pressure
1. Oil pump steering error or oil pump damage.
2. Is the pressure gauge damaged?
3. The pressure control valve has no electric signal or valve blockage.
4. Pressure cartridge valve plug, card, can not seal oil.
5. The filling valve is stuck (the slider is not slow).
6. The compensation amplifier is too small.
7. The pressure can only reach a certain value. Use the method of directly giving 24V to judge whether


there is a problem with the valve oil pump.
Third, the pressure is built slowly (REXROTH hydraulic system)
1. The pressure hole at the X port of the pressure valve may be blocked.
2. The cartridge valve at the pressure valve may not be flexible.
3. Electrically possible problems: use the 24V voltage test directly to the electromagnetic pressure valve,
or use the electromagnetic pressure valve spool test.
4. Is the high pressure oil filter blocked?


Fourth, there is a shock when going down
1. Impact sound caused by looseness of the guide rail.
2. The position of the black chip of the grating ruler is incorrect.
3, fast down before the delay parameter setting value is too small.


Five, the slider has no fast action
1. Quickly lower the valve with or without electric signal or stuck.
2. The electromagnetic proportional directional control valve has no electric signal or the spool has no
action, and it is stuck (check the feedback voltage).
3. The mechanical part is too tightly connected, such as the rail plate is too tight, the cylinder is too
tight.
4. The filling valve is closed and cannot be opened, so that it cannot absorb oil.
5. Scale rule problem.
6. Is the foot switch intact, check the wiring.
7. After the slow valve is energized, the filling valve is closed and the upper chamber cannot absorb oil.


Sixth, the slider speed conversion point has a long pause time
1. Intake air in the upper chamber of the cylinder, the pressure builds up for a long time (leakage from
the self-priming line).
2. The flow rate of the filling valve or the self-priming pipe is small, or the speed of the slider is too fast,
causing vacuum suction.
3. The filling valve is not completely closed and the upper chamber pressure is slowed down.
4. After the slow valve is energized, the filling valve is closed and the upper chamber cannot absorb oil.
5. The neutral position of the proportional valve causes the opening to be different and goes out of
sync.
6. Will the speed of the fast down test be paused?
7. The magnitude of the rapid downforce affects the closing of the filling valve, eliminating the rapid
downforce.
8. Pressure parameter adjustment in the delay phase before the work.
9. The filling valve control line damping hole is too small to form a pressure difference.
10. CNC system parameters (slow down delay).
11. CNC system parameters (slow down gain parameter reduction).


Seven, the slider does not slow down
1. Electromagnetic proportional directional control valve has no electric signal or the spool has no
action, stuck.
2. The system cannot establish pressure.
3. The filling valve is stuck, or the filling valve seal leaks.
4. Slow down the valve with or without electric signal or stuck.
5. The back pressure is too high or the pressure is too low.


Eight, the slider shakes slowly when moving slowly, swings, and has noise
1. Cylinder discharge pressure oil contains air bubbles.
2. The friction of the slider guide is too large, and there is no lubricant.
3. The gap between the rail plate fitting surface is large, or the upper and lower sides are uneven.
4. The rack and workbench levels are not adjusted well.
5. Balance valve blockage.
6. Check if the quick lower valve is energized to open.
7. CNC system parameters (gain), or work speed setting too large.
8. The back pressure valve is loose and the resistance on both sides is different.
9. Is the electromagnetic proportional valve coil biased and the proportional valve median signal
correct?
10. Is the signal of the proportional servo valve interfered? The inspection method is the same as
above.
11. The cylinder seal ring locks the piston rod and the resistance is high (change the PTFE hard seal
test).
12. The spherical washer on the scale is not installed, the movement of the slide is not smooth, and
there is a problem with the communication line of the scale.
13. The pressure curve is wrong, and the pressure is not enough when entering the work.
14. Filling valve pressure seal O-ring produces a small amount of leakage.


Nine, the synchronization deviation is slow when slow down
1. Synchronous detection system failure (grating ruler).
2. Proportional direction reversing valve.
3. Quick down valve leakage.
4. The back pressure difference between the two sides is large.
5. The oil temperature is too low.
6. Oil cylinders in the upper and lower chambers.
7. CNC system parameters.


Tenth,The slider oscillates and shakes when it is under pressure at the bottom dead center.
1. The grating ruler may have a problem.
2. Cylinder discharge pressure oil contains bubbles.
3. Balance valve is blocked.
4. CNC system parameters (gain).
5. Back pressure valve problem, the resistance on both sides is different.
6. Electromagnetic proportional valve problem: the median may not be correct.
7. Cylinder lifting bolt loose → bottom dead point jitter, the contour is wrong, the bending angle is not
accurate, there is a sound when bending.


Eleventh, the slider has no backhaul action or the return journey is very slow
1. Is the electromagnetic proportional directional control valve reversible and damaged?
2. Does the system establish pressure or the return pressure is too small?
3. There may be a side of the filling valve stuck or not fully open.
4. After the slow down valve is energized, close the filling valve and cannot return quickly.
5. CNC system: the programming angle is too small to be able to bend to the bottom of the bend
programming.
6. CNC system parameter zeroing.
7. Scale damage or cable problem.
8. Check if the system pressure is built slowly.


Twelfth,the slider shakes and shakes when returning
1. The return pressure is too high or too low.
2. System parameters or PLC and DM02 modules.
3. Proportional valve coil with or without deflection.


Thirteenth, the slider slides (top dead center)
1.Back pressure valve adjustment.
2. Back pressure valve leakage or quick lower valve leakage.
3. Oil tanks in the upper and lower chambers.
4. Proportional valve offset.
5. The stability of the seal support is not enough. After the deformation, the slider slides down.
6. Determine the cause of the slip - Observe the lower port oil after removing the proportional valve.


Fourteenth, the bending angle error is large
1. Check if the compensation cylinder compensation deflection is large and cannot completely recover
the zero position.
2. Check if the quick clip is loose.
3. check whether there is no change in the dead point under each bend.
4. check whether the bow wrench installation is standard, whether the screw hole is dead
5. the change of the board itself (thickness, material, stress).
6. Is the grating ruler loose?
7. The positioning accuracy is not accurate: Is the proportional valve zero offset value suitable? The
positioning cannot go to the bottom dead center so that it cannot be returned.


Fifteenth, the straightness error of the bend is large
1. Check if the compensation cylinder compensation deflection is appropriate.
2. Check if the quick clip is loose.
3. Check whether the horizontal and vertical mold fitting surfaces on the slider are deformed.
4, check whether the upper and lower molds are deformed.
5. the change of the board itself (thickness, material, stress).
6. Check if the lower table (neutral plate) is deformed.


Sixteenth, hydraulic pipeline oil leakage or oil pipe collapse
1. Check if the tubing installation meets the requirements (extension length, pipe diameter, wall
thickness, ferrule, nut too tight, too loose, bending radius, etc.).
2. Does the tubing have shock and vibration?
3. Check if the pipeline collides with other interference.
4. The pipe is not fixed by pipe clamp.


Seventeenth,Precautions for installation and maintenance of hydraulic system:
1. The valves of the paint seal shall not be dismantled by themselves, and shall not be adjusted.
2. After the valve is cleaned, it must work immediately. It must be replaced with new oil and cleaned.
3. When the oil pump is installed, it must not be subjected to any knocking or impact. Before the oil
pump is tested, it must be pre-fueled.
4. Each valve can only be transported with its valve body and must not touch any solenoid valve.


Eighteenth, the common fault analysis of the back gauge
1.the back gauge can not move:
(1) check the drive for alarm.
(2) check each axis limit switch.
(3) check the reliability of the connector.
2.the drive alarm:
3. X, R axis is not stable, there is jitter
4. positioning accuracy changes:
(1)mechanical problem (with or without looseness, impact).
(2)electrical → one-way positioning.
(3)parameter adjustment.
(4) Is the tensioning wheel loose, and the screw connecting screw is loose?
5. overload alarm: whether the ball screw can rotate easily, the steel ball may be damaged.
6. R-axis drive No. 16 alarm → gas spring is broken.
7. Z1, Z2 axis 22 alarm → replace the encoder cable.
8. alarm No. 38 → the line connector is loose.
9. the servo motor makes noise: the gain setting is too large.



分享到: